Research Laboratory
Optical and Confocal Microscopy
Clinical pathology
General Equipment
In vitro fertilization
Medical Genetics
Nephrology
Osmometers, Colon Counter, Anoxomat and Spiral Plating
Ovens and CO2 Incubators
Pathologic anatomy
Refrigerators & Freezers
Scientific investigation
Sterilization
 
 
 
Budget request
 
 
 
Filsat In vitro fertilization  
 
 
Products  
 
See it all
CelCulture CO2 Incubators
  • Capacities of 50L, 170L or 240L
  • ULPA filtering (99.999%)
  • Infrared CO2 control sensor
  • Direct Heat Flow
  • 37 ° C / 5% CO2 / 85-90% Relative Humidity
  • Forced Convection
  • Steam Sterilization Cycle at 90.0 ° C
Research Laboratory Read +
 
IVF Multi-Area Workstation
 
  • ISO Class III Workspace
  • Working surface with multiple heating zones
  • ULPA filter
  • Vertical Laminar Flow
  • Power Reduction by 40% vs. Horizontal Flow
  • Airflow Management
  • Management System with Data Logging
  • Space for 1 microscope
Research Laboratory Read +
 
MIRI - Incubator for IVF w / Time Lapse
  • 6 physically separate incubation chambers (up to 6 patients)
  • Up to 14 embryos per incubation chamber (total 84 embryos)
  • TIME-LAPSE system with image capture at 5-minute intervals
  • Direct heating and thermal cap
  • No need for pre-mixed gases (CO2 and N2)
  • Software with patient ID creation per camera
  • Intuitive software with image and event management
  • Stacking of images
  • TIME-LAPSE for each of the 14 wells in each chamber
  • Color Monitor and Digital Control Panel
  • HEPA / VOC Filters
  • Sama temperature: 25 - 40ºC
Research Laboratory Read +
 
MIRI - Multi-room incubator for IVF
  • 6 physically separate incubation chambers (up to 6 patients)
  • Total capacity: 24 x 4-well IVF / 24 x Petri plates with Ø60mm / 48 x Ø35mm petri plates
  • Direct heating and thermal cap
  • Independent temperature regulation per camera
  • Temperature recovery in less than 1 minute and gas in less than 3 minutes
  • Temperature Range: 25 - 40ºC
  • No need for pre-mixed gases (CO2 and N2)
  • CO2 range: 1.9-10%
  • O2 range: 20-5%
  • HEPA / VOC Filters
  • UV Sterilization
  • According to IEC / EN 60601-1 (3rd Edition)
  • Possibility to connect PC to data logging
Research Laboratory Read +
 
 
Top Brands
Subscribe to our newsletter
Cancel subscription
Follow Us  
Privacy Policy      Cookies Policy      RAL e RLL
livro
Filsat © 2013. All rights reserved
Development Netgócio ®
We use our own and third-party cookies to offer you a better experience and service. To know which cookies we use and how to disable them, read the cookies policy.
By ignoring or closing this message, and unless you have disabled cookies, you agree to its use on this device.